Malfunction, cause and remedy
21
Malfunctions electrics/electronics
21.1
BiG Pack 1270
Original Operating Instructions 150000747_02_en
265
Possible cause
Remedy
The wiring of the sensor is de-
fective.
Check sensor and wiring for damage,
.
522109-
B 1
Sensor B1 “Flywheel brake“
Possible cause
Remedy
FMI 4: An undervoltage or a short circuit to ground has occurred.
FMI 5: A cable break has occurred or the current intensity is too weak.
The sensor shows external
damage.
Check sensor and wiring for damage,
.
The wiring of the sensor is de-
fective.
522111-
B11
Sensor B11 “Bale chute“
Possible cause
Remedy
FMI 4: An undervoltage or a short circuit to ground has occurred.
FMI 5: A cable break has occurred or the current intensity is too weak.
The sensor shows external
damage.
Check sensor and wiring for damage,
.
The wiring of the sensor is de-
fective.
522112-
B19
R
Sensor B19 “Force sensor right“
Possible cause
Remedy
FMI 4: An undervoltage or a short circuit to ground has occurred.
FMI 5: A cable break has occurred or the current intensity is too weak.
The sensor shows external
damage.
Check sensor and wiring for damage,
.
The wiring of the sensor is de-
fective.
522113-
B18
L
Sensor B18 “Force sensor left“
Possible cause
Remedy
FMI 4: An undervoltage or a short circuit to ground has occurred.
FMI 5: A cable break has occurred or the current intensity is too weak.
The sensor shows external
damage.
Check sensor and wiring for damage,
.
The wiring of the sensor is de-
fective.