Terminal – Menus
13
Menu 15 "Settings" 13.16
BiG Pack 1270
Original Operating Instructions 150000747_02_en
179
13.16.2
Menu 15-2 "Actuator test"
WARNING
Risk of injury due to non-observance of safety instructions
If the relevant safety routines are not observed, persons may be seriously injured or killed.
The safety routines must be read and observed to avoid accidents,
.
The actuator test is used to test the actuators installed on the machine. An actuator can only be
tested when current is flowing through it. Therefore, in the "Actuator test" menu, the actuator
must be controlled manually for a short time in order to determine possible errors in the actuator
system.
15-2
state: 2
OFF
K01
K02
EQ001-080 / EQ000-046
Observe the safety routine "Run actuator test",
.
ü
To open the menu, press
.
Æ
The display shows the "Actuator test" menu.
Possible actuators (depending on how the machine is equipped)
There is an overview of the position of the sensors, actuators and control units in the circuit
diagram,
No.
Actuator
Designation
K01
K01
(Extend) main valve
K02
K02
(Retract) main valve
K03
K03
Bale chute piston surface
K04
K04
Bale chute annular surface
K05
K05
Bale ejector plunger surface
K06
K06
Bale ejector annular surface