21
Malfunction, cause and remedy
21.1
Malfunctions electrics/electronics
238
BiG Pack 1270
Original Operating Instructions 150000747_02_en
FMI
Meaning
20
The data deviates upwards.
21
The data deviates downwards.
31
The condition has been fulfilled.
21.1.2
Overview of control units
A10
A14
A20
A30
A40
A10
A14
A20
A30
A40
BPG000-074
Electrical component identification (ECI):
ECI
Designation
ECI
Designation
A10
KRONE Machine Controller (KMC)
A30
Force measurement amplifier weigh-
ing device (FMA2)
A14
Moisture sensor (RMS)
A40
Distributor central electrical system
A20
Force measurement amplifier for bal-
ing force control (FMA 1)