Malfunction, cause and remedy
21
Malfunctions electrics/electronics
21.1
BiG Pack 1270
Original Operating Instructions 150000747_02_en
279
Possible cause
Remedy
The wiring of the actuator is
faulty.
Check actuator and wiring for damage,
522330-
K100
Actuator K100 „Warning beacon“ (rear)
Possible cause
Remedy
FMI 5: A cable break has occurred or the current intensity is too weak.
FMI 6: There is a short circuit to ground or current intensity is too low.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
The wiring of the actuator is
faulty.
522331-
K100
Actuator K100 “Warning beacon“ (front)
Possible cause
Remedy
FMI 5: A cable break has occurred or the current intensity is too weak.
FMI 6: There is a short circuit to ground or current intensity is too low.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
The wiring of the actuator is
faulty.
522332-
FMA2
Force measurement amplifier 2, channel 1 (FMA 2) "Weighing device"
Possible cause
Remedy
FMI 0: The upper limit value was greatly exceeded.
FMI 1: The lower limit value was far below the required one.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522333-
FMA2
Force measurement amplifier 2, channel 2 (FMA 2) "Weighing device"
Possible cause
Remedy
FMI 0: The upper limit value was greatly exceeded.
FMI 1: The lower limit value was far below the required one.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.