21
Malfunction, cause and remedy
21.1
Malfunctions electrics/electronics
250
BiG Pack 1270
Original Operating Instructions 150000747_02_en
521107-
High
Supply voltage for the KRONE Machine Controller (KMC) at connection UE
Possible cause
Remedy
FMI 3: An overvoltage or a short circuit to the supply voltage has occurred.
The cabling is faulty.
Check the cabling for damage,
.
One or several sensors/actu-
ators connected to the voltage
group are defective.
An overview of the position of the sensors, actuators and
control units is provided in the circuit diagram,
Check the sensor and cabling for damage,
The control unit KMC is de-
fective.
Replace the control unit KMC.
Note the error number with the FMI and contact the KRONE
service partner.
521107-
Low
Supply voltage for the KRONE Machine Controller (KMC) at connection UE
Possible cause
Remedy
FMI 4: An undervoltage or a short circuit to ground has occurred.
The cabling is faulty.
Check the cabling for damage,
.
One or several sensors/actu-
ators connected to the voltage
group are defective.
An overview of the position of the sensors, actuators and
control units is provided in the circuit diagram,
Check the sensor and cabling for damage,
The control unit KMC is de-
fective.
Replace the control unit KMC.
Note the error number with the FMI and contact the KRONE
service partner.
522000-
Central lubrication system
Possible cause
Remedy
FMI 7: The mechanism does not respond or an expected event does not occur.
No flow of lubrication detected
despite lubrication being act-
ive.
Refill lubricant.
Clean the central lubrication.
Check the electrical system and the pump.
522001-
Flywheel brake
Possible cause
Remedy
FMI 7: The mechanism does not respond or an expected event does not occur.
The flywheel brake is en-
gaged and the universal shaft
is rotating.
Release the flywheel brake.