21
Malfunction, cause and remedy
21.1
Malfunctions electrics/electronics
274
BiG Pack 1270
Original Operating Instructions 150000747_02_en
522303-
K12
Actuator K12 “Coupling feed rotor“
Possible cause
Remedy
FMI 5: A cable break has occurred or the current intensity is too weak.
FMI 6: There is a short circuit to ground or current intensity is too low.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
The wiring of the actuator is
faulty.
522304-
K02
Actuator K02 „(Retract) main valve“
Possible cause
Remedy
FMI 5: A cable break has occurred or the current intensity is too weak.
FMI 6: There is a short circuit to ground or current intensity is too low.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
The wiring of the actuator is
faulty.
522305-
K01
Actuator K01 „(Extend) main valve “
Possible cause
Remedy
FMI 5: A cable break has occurred or the current intensity is too weak.
FMI 6: There is a short circuit to ground or current intensity is too low.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
The wiring of the actuator is
faulty.
522306-
K07
Actuator K07 „Blade cassette plunger surface“
Possible cause
Remedy
FMI 5: A cable break has occurred or the current intensity is too weak.
FMI 6: There is a short circuit to ground or current intensity is too low.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
The wiring of the actuator is
faulty.
522307-
K08
Actuator K08 „Blade cassette plunger surface“
Possible cause
Remedy
FMI 5: A cable break has occurred or the current intensity is too weak.
FMI 6: There is a short circuit to ground or current intensity is too low.
The actuator is damaged ex-
ternally.