
Malfunction, cause and remedy
21
Malfunctions electrics/electronics
21.1
BiG Pack 1270
Original Operating Instructions 150000747_02_en
259
522053-
5
Upper twine 5
Possible cause
Remedy
FMI 0: The upper limit value was greatly exceeded.
On the upper twine, the min-
imum twine length has benn
exceeded during packer feed.
Have the sensor adjusted.
522054-
6
Upper twine 6
Possible cause
Remedy
FMI 0: The upper limit value was greatly exceeded.
On the upper twine, the min-
imum twine length has benn
exceeded during packer feed.
Have the sensor adjusted.
522057-
B10
Knotter monitoring
Possible cause
Remedy
FMI 1: The lower limit was significantly undershot.
The knotter shaft has not ro-
tated within one plunger
stroke.
Have the B10 sensor "Knotter monitoring" set.
522058-
M1
Knotter motor
Possible cause
Remedy
FMI 1: The lower limit value was far below the required one.
The knotting process has not
been finished withing two
plunger strokes.
Check the electrical system of the knotter motor.
Check the mechanics in the area of the knotter triggering.
Have the sensor adjusted.
522059-
MultiBale
Possible cause
Remedy
FMI 1: The lower limit value was far below the required one.
The switchover entire bale/
MultiBale has not been con-
cluded within 2 plunger
strokes.
Check the mechanics in the area of the knotter triggering.
Check the electronics in the area of the "MulitBale" locking.
Have the sensor adjusted.