21
Malfunction, cause and remedy
21.4
Malfunctions on the double knotter
296
BiG Pack 1270
Original Operating Instructions 150000747_02_en
Possible cause
Remedy
8.1
The upper tensioning arm
does not work properly.
Not enough twine tension on
the upper twine strand.
Check the upper tensioning arms for easy running.
Check the free space on the upper tensioning arm, see
6.3
Increase the twine tension on the upper twine strand,
see 2.5,
8.2
The lower twine tension spring
is broken or released.
Replace or tighten the lower twine tension spring, see 2.2,
8.3
The twine tension on the
lower twine strand is insuffi-
cient.
Tighten the twine brake on the lower twine strand, see 2.2,
8.4
The twine driver starts work-
ing too late.
Check the setting of the twine driver. Adjust it, if necessary,
8.5
There is too much knotter
needle overrun in the upper
dead point.
Check the knotter needles,
.