Terminal – Menus
13
Menu 15 "Settings" 13.16
BiG Pack 1270
Original Operating Instructions 150000747_02_en
175
15-1
state:
8,3V
7,3V
5,2V
2,4V
7,8V
1
B 1
B 2
EQ001-080 / EQ000-040
ü
To open the menu, press
.
Æ
The display shows the "Sensor test" menu .
Icon
Designation
Explanation
Select previous sensor
Select next sensor
Exit menu
Setting values
The minimum and maximum setting value with attenuated sensor (metal in front of the sensor)
are shown in the upper part of the bar display. The current setting value (actual value) is
displayed under the bar display.
The distance from the sensor to the metal must be adjusted so that in the attenuated state the
bar is in the upper marking. Then check whether the bar is in unattenuated state in the lower
marked area.
Possible sensors (depending on the machine configuration)
There is an overview of the position of the sensors, actuators and control units in the circuit
diagram,
Electrical component identification (ECI):
ORI
Sensor
Designation
B1
B 1
Flywheel brake
B3
B 3
Central lubrication
B4
B 4
Plunger at rear (measuring)
B5
B 5
Front plunger (calibrate)