Maintenance – electrical system
360
Pos: 234.7 /Überschriften/Überschriften 3/A-E/E/Einstellung der Sensoren @ 0\mod_1199962173428_78.docx @ 37635 @ 3 @ 1
22.3.1
Adjusting the Sensors
Pos: 234.8 /BA/Wartung/Sensoren/Namursensor d = 12 mm @ 0\mod_1199962247038_78.docx @ 37654 @ 4 @ 1
22.3.1.1
Namur sensor d = 12 mm
a
BP-VFS-088-1
2
1
3
Figure 231
The dimension between the encoder (2) and the sensor (1) must be "a" = 2 mm
.
Setting
•
Loosen the nuts on either side of the sensor.
•
Turn the nuts until dimension "a" = 2 mm
is reached.
•
Tighten the nuts again.
Pos: 234.9 /BA/Wartung/Sensoren/Namursensor d = 30 mm a= 5mm @ 0\mod_1199962520100_78.docx @ 37673 @ 4 @ 1
22.3.1.2
Namur sensor d = 30 mm
a
BPXC0172
2
1
3
Figure 232
The dimension between the encoder (2) and the sensor (1) must be "a" = 5 mm
.
Setting
•
Loosen the nuts on either side of the sensor.
•
Turn the nuts until dimension "a" = 5 mm
is reached.
•
Tighten the nuts again.