Pos: 125.41 /BA/Info-Center/Ladewagen/Medium/Parameter Querförderband aktivieren/deaktivieren @ 141\mod_1355742154906_78.docx @ 1253883 @ 2 @ 1
9.16
Parameter „Cross Conveyor“ Optional (Only For GD Design)
Fig. 68
Bar graph on:
Parameter “cross conveyor” activated.
Bar graph off:
Parameter “cross conveyor” deactivated.
In case the wagon is equipped with a cross conveyor ex works, the “cross conveyor” parameter
is set ex works.
If a cross conveyor is installed subsequently or if the job computer has been replaced, the
parameter “cross conveyor” must be activated once.
Checking and setting “cross conveyor” parameter:
•
Switch on the sensor test (refer to chapter KRONE operation terminal Alpha entitled
“Sensor Test”).
• Press
the
key (8).
Indicator lamp (2) goes out and indicator lamp (8) flashes.
Deactivating “cross conveyor” parameter:
• Press
the
key (9).
The “cross conveyor” parameter is deactivated, the bar graph is off.
Activating “cross conveyor” parameter:
• Press
the
key (10).
The
“cross conveyor” parameter is activated, the bar graph is on.
If the parameter is activated, the cross conveyor is operated via the control unit (separate
hydraulic connection) of the tractor.
Switching off the control unit:
• Press
the
key
Pos: 125.42 /Layout Module /---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1