KRONE operation terminal Alpha
112
Pos: 125.31 /BA/Info-Center/Ladewagen/Medium/Sensortest @ 179\mod_1375705820745_78.docx @ 1539749 @ 2 @ 1
9.13 Sensor
Test
AX000034_2
Fig. 63
In the sensor test, the sensors installed on the machine are checked for faults.
If the job computer has been replaced, it is necessary to check the parameters for the machine
in the sensor test and to change them, if necessary.
Switching sensor test on
The control unit must be turned off.
• Press
the
key and hold it and press the
key.
The control unit switches to the sensor test, the indicator lamp (2) flashes.
Possible sensors (depending on how the machine is equipped)
No. Sensor designation
Status options
11
P.T.O. shaft sensor, for the version without
automatic loader
1,2,3
Automatic loader sensor, for the automatic
loader version
1,2,3
17 Blade
sensor
1,2,3
18
Sensor for axle locked
*
1
19
Sensor wagon full
1,2,3
20
Sensor tailgate
1,2,3
*1 Axle locked; indicator lamp (18) is lit: Pressure above 100 bar.
Axle not locked; indicator lamp (18) off: Pressure below 100 bar.
Status options
1 LED on : alive (iron in front of the sensor)
2 LED off : not alive (no iron in front of the sensor)
LED flashing: sensor defective (e. g. cable break or short circuit)
Pos: 125.32 /Layout Module /---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1