KRONE ISOBUS Terminal - Menus
243
Pos: 129.173 /BA/Info-Center/CCI-ISOBUS-Terminal/CCI-Ladewagen/Alarmmeldungen/2) Logische Alarme 01 bis 11_CCI @ 185\mod_1379398171666_78.docx @ 1592523 @ @ 1
No.
Figure
Possible cause
Remedy
1
1
FULL
–
The wagon is full.
–
The tailgate is closed and the floor
conveyor switch-off sensor is switched.
– Empty the wagon.
2
2
min
-1
–
The speed of the discharge rollers is too
low or the discharge rollers are at a
standstill.
–
The wagon is full, the tailgate is open,
the floor conveyor supply is activated and
the discharge roller speed is too low.
– Check the discharge
roller drive.
For ZX:
–
The wagon is full, the tailgate is open,
the floor conveyor supply is activated and
the discharge roller speed is too low
–
The tailgate is open, the floor conveyor
supply is activated and the P.T.O. shaft
is not activated
– Check the discharge
roller drive.
– Switch on the P.T.O.
shaft.
3
3
min
0
-1
–
The P.T.O. speed is too high.
–
The P.T.O. shaft is not stopped and an
attempt was made to open the tailgate.
– Switch off PTO shaft and
only then open the
tailgate.
4
4
–
The steering axle is not locked.
–
The tailgate was opened and the steering
axle was not locked.
– Lock the steering axle on
the sile pile before
opening the tailgate.
6
6
–
The payload is reached.
– Complete the loading
process.
11
11
–
The blades are not turned on (blade
monitoring).
–
The blades have moved out of the “Blade
on” position.
– Switch blades on again.