![Krone AX 250 D Original Operating Instruction Download Page 362](http://html1.mh-extra.com/html/krone/ax-250-d/ax-250-d_original-operating-instruction_2004854362.webp)
Maintenance – electrical system
362
Pos: 240 /Überschriften/Überschriften 2/A-E/Abschaltung des Kratzbodens (GD) @ 1\mod_1201250360479_78.docx @ 52482 @ 2 @ 1
22.5
Switching off the Floor Conveyor (GD)
Pos: 241 /BA/Wartung/Ladewagen/Abschaltung des Kratzbodens Bild AX (GD) @ 3\mod_1203601649283_78.docx @ 67353 @ @ 1
1
AX000013
50h
2
Figure 234
Pos: 242 /BA/Wartung/Ladewagen/Abschaltung des Kratzbodens (GD) @ 0\mod_1199967309756_78.docx @ 37837 @ @ 1
The right bearing of the lower discharge roller is movably mounted. The motion sensor (1) is
located on the bottom of the bearing. It records the offset of the discharge roller.
Movement of the support
The switch-off movement of the sensor is determined by a tension spring (2).
•
Tighten tension spring (2) = longer switch-off delay = more force acting on the discharge
rollers
•
Loosen tension spring (2) = shorter switch-off delay = less force acting on the discharge
rollers
Note
Free movement of the bearing must be ensured. It must therefore be regularly lubricated with a
grease gun, in any case at least every 50 operating hours.