Section 4: System operation
Selecting this function places the alarm panel into user walk test mode. The Ready, Armed and Trouble LEDs on the keypad
flash to indicate that the test is active. If zones are tripped during a walk test, the system sounds a steady 2-second tone on
all keypads and the main bell to indicate that the zone is working correctly.
The walk test can be stopped at any time by re-entering [*][6][Master Code][08] on the keypad. The test automatically ter-
minates after 15 minutes of inactivity. An audible warning begins 5 minutes prior to automatic termination.
Note:
Fire and CO alarms are not tested in user's walk test. If a fire or CO alarm is detected, walk test ends automatically and the
appropriate reporting codes are sent immediately to the monitoring station. Refer to the manufacturers instructions provided with
CO and Fire detectors for testing. This feature is not available in CP-01 systems.
Late to Open
Menu: [*][6][Master Code] > Late To Open
Keypad: [*][6][Master Code] + 09
This function enables or disables the Late to Open option. This option sends a reporting code to the central monitoring sta-
tion if the partition has not been disarmed by a programmed time.
Other programming options that may affect this function:
See "[201] Open/Close Events 1", option "[211] Miscellaneous Open/Close Events" on page 118.
Late to Open Time
Menu: [*][6][Master Code] > Late To Open Time
Keypad: [*][6][Master Code] + 10
This function is used to program the time of day the partition must be disarmed by when the Late to Open option is enabled.
A separate time can be programmed for each day of the week. Valid data entries are 00:00 - 23:59. 99:99 disables the late to
open feature for the selected day.
Select a day of the week by scrolling while in the Late to Open menu, or by using keys 1-7 to select Sunday to Saturday
respectively.
Brightness Control
Menu: [*][6][Master Code] > Brightness Control
Keypad: [*][6][Master Code] + 12
This function is used to change the brightness level of keypad display backlighting. Use the scroll keys to increase and
decrease brightness or enter a value from 00 to 15. Selecting 00 turns off keypad backlighting.
Contrast Control
Menu: [*][6][Master Code] > Contrast
Keypad: [*][6][Master Code] + 13
This function is used to change the contrast level of keypad displays. Use the scroll keys to increase and decrease contrast
or enter a value from 00 to 15. Selecting 00 turns off keypad contrast.
Buzzer Control
Menu: [*][6][Master Code] > Buzzer Control
Keypad: [*][6][Master Code] + 14
This function is used to change the volume level of keypad buzzers.
Use the scroll keys (LCD keypads) or the [*] key (LED/ICON keypads) to increase and decrease volume or key in a value
from 00 to 15. Selecting 00 turns off the keypad buzzer.
Note:
For UL/ULC listed installations, do not turn off the keypad sounder.
Authorize Firmware Update
Menu: [*][6][Master Code] > Authorize Update
Keypad: [*][6][Master Code] + 17
This function is used to give authorization to the system to start the firmware upgrade process after all firmware upgrade files
for the keypads, HSM2HOST and control panel have been fully downloaded.
Once this option is activated, the keypads and system automatically exit [*][6] and indicate that the firmware update is in pro-
gress.
Interactive Services
Menu: [*][6][Master Code] > Interactive Serv
- 69 -