Appendix 1: Reporting codes
Section #
Definition
Dialer
Direction*
Automatic Contact ID
Codes
SIA Auto Rep Codes**
[308]-[101]
HSM3350: 3A Power supply module #1-4 tamper/restored
T/R
E(3)41-(651-654)
R(3)41-(651-654)
ES-(0651-0654)
EJ-(0651-0654)
[308]-[101]
Keypad Lockout - Incorrect access code entry
T/R
E(4)61-000
JA-0000
Opening Events
[308]-[201]
User Openings - Disarmed by user
O/C
E(4)A1-UUU
OP-UUUU
[308]-[202]
Automatic Arming Canceled
O/C
E(4)64-UUU
CI-0000
[308]-[201]
Special Opening - System disarmed using: keyswitch,
maintenance code, DLS software, wireless key
O/C
E(4)AA-000
OP-0000
[308]-[211]
Late to Open - System not disarmed before late to open time
expired
O/C
E(4)53-000
CT-0000
[308]-[202]
Automatic (Schedule) Opening
O/C
E(4)A3-000
OA-0000
[308]-[201]
Keyswitch Open
O/C
E(4)A9-ZZZ
OS-ZZZZ
Closing Events
[308]-[201]
User Closings - System armed by user, wireless key
O/C
R(4)A1-UUU
CL-UUUU
[308]-[221]
Partial Closing - 1 or more zones bypassed when armed
O/C
E(4)56-000
CG-0000
[308]-[201]
Special Closing - System armed via: quick arm, keyswitch,
function key, maintenance code, DLS software
O/C
R(4)AA-000
CL-0000
[308]-[211]
Late to Close - Auto-arm prealert sounded
O/C
E(4)54-000
CI-0000
[308]-[211]
Exit Fault
O/C
E(3)74-ZZZ
EA-ZZZZ
[308]-[202]
Automatic (Schedule) Closing
O/C
R (4)A3-000
CA-0000
[308]-[201]
Keyswitch Close
O/C
R(4)A9-ZZZ
CS-ZZZZ
System Trouble Events
[308]-[301]
Battery trouble/restore - Main panel
MA/R
E(3)A2-000 / R(3)A2-000
YT-0000 / YR-0000
[308]-[301]
Battery absent trouble/restore - Main panel
MA/R
E(3)11-000 / R(3)11-000
YM-0000 / YR-0000
[308]-[301]
Power unit failure trouble/restore
MA/R
E(3)14-000 / R(3)14-000
YP-0000 / YQ-0000
[308]-[301]
Panel AC trouble/restore - Main panel
MA/R
E(3)A1-000 / R(3)A1-000
AT-0000 / AR-0000
[308]-[302]
Bell circuit trouble/restore
MA/R
E(3)21-000 / R(3)21-000
YA-9999 / YH-9999
[308]-[302]
TLM (telephone line) fail/restore
MA/R
E(3)51-000 / R(3) 51-000
LT-0001 / LR-0001
[308]-[302]
Auxiliary power trouble/restore
MA/R
E(3) 12-000 / R(3) 12-000
YP-0000 / YQ-0000
[308]-[302]
Corbus output fault/restore
MA/R
E(3)12-000 / R(3)12-000
YP-0000 / YQ-0000
[308]-[302]
Panel overcurrent trouble/restore
MA/R
E(3)12-000 / R(3)12-000
YI-0000 / YJ-0000
[308]-[305]
PGM 2, 2-Wire smoke trouble/restore
MA/R
E(3)73-992 / R(3)73-992
FT-0992 / FJ-0992
Module Troubles
[308]-[332]
Hardwired Module Low Voltage trouble/restore - Keypads
MA/R
E(3)AA-001-016
R(3)AA-001-016
EM-0001-0016
EN-0001-0016
[308]-[332]
Hardwired Module Low Voltage trouble/restore - HSM2108
MA/R
E (3)AA-101-130
R (3)AA-101-130
EM-0101-0130
EN-0101-0130
[308]-[332]
Hardwired Module Low Voltage trouble/restore - HSM2208
MA/R
E(3)AA-201-216
R(3)AA-201-216
EM-0201-0216
EN-0201-0216
[308]-[332]
Hardwired Module Low Voltage trouble/restore - HSM2HOST
MA/R
E (3)AA-551
R (3)AA-551
EM-0551
EN-0551
[308]-[332]
Hardwired Module Low Voltage trouble/restore - HSM2204
MA/R
E(3)AA-601-604
R(3)AA-601-604
EM-0601-0601
EN-0601-0604
[308]-[332]
Hardwired Module Low Voltage trouble/restore - HSM2300
MA/R
E (3)AA-621-624
R (3)AA-621-624
EM-0621-0624
EN-0621-0624
- 251 -