Section 5: Programming
[201]-[208] Partition Zone Assignment
Zones can be assigned to any partition. Global zones are zones assigned to more than one partition. A global zone is only
armed when all assigned partitions are armed. The zone is disarmed when any of the assigned partitions is disarmed. By
default, zones 1 through 8 are assigned to partition 1.
To assign zones to partitions, first select a partition [201]-[231], then select a zone group [001]-[016] and then a zone (1-248):
Zone Group
Zones
Zone Group
Zones
001
1-8
017
129-136
002
9-16
018
137-144
003
17-24
019
145-152
004
25-32
020
153-160
005
33-40
021
161-168
006
41-48
022
169-176
007
49-56
023
177-184
008
57-64
024
185-192
009
65-72
025
193-200
010
73-80
026
201-208
011
81-88
027
209-216
012
89-96
028
217-224
013
97-104
029
225-232
014
105-112
030
233-240
015
113-120
031
241-248
016
121-128
All zones assigned to a partition are supervised and operate according to the zone type programmed. If a zone is not
assigned to a partition, it is not supervised and all activity on the zone is ignored by the system.
[300] Panel/Receiver Communication Paths
This section is used to select the path of communications between the alarm system and the central station.
Paths can be established through either the alarm system’s on-board Public Switched Telephone Network (PSTN) con-
nection through the on board Ethernet or through the optional cellular communicator.
Paths to four receivers can be programmed using sections 001 - 004. The communications path for each receiver is defined
by selecting one of the following six options:
[01] Phone Line
Events are communicated through the alarm system phone line programmed in section [301]. If Phone Line is selected for
receiver 1, the phone number programmed in section [301] option [001] is used. If Phone Line is selected for receiver 2, the
phone number programmed in section [301] option [002] is used, etc.
[02] Alternate Communicator Auto Routing
Selecting this option enables the alternate communicator to determine which communications path to use (Ethernet
primary/secondary, and/or cellular primary/secondary). See section [851] Alternate Communicator Programming for details.
[03] Alternate Communicator Receiver 1
Events are communicated through Ethernet receiver 1.
[04] Alternate Communicator Receiver 2
Events are communicated through Ethernet receiver 2.
[05] Alternate Communicator Receiver 3
Events are communicated through cellular receiver 3.
[06] Alternate Communicator Receiver 4
Events are communicated through cellular receiver 4.