Appendix 5: Regulatory approvals
The local control unit and the local power supply must be protected in one of the following ways:
l
The control unit and audible alarm device must be in a protected area which is armed 24 hours a day.
l
Each partition must arm the area protecting the control unit and the audible alarm device power supply. This may require duplicate protection armed by each par-
tition. Access to this protected area, without causing an alarm, will require that all partitions be disarmed.
l
In all cases described above, the protected area for the control unit must be programmed as not-bypassable.
Casual Users
The installer should caution the user not to give system information (e.g., codes, bypass methods, etc.) to casual users (e.g., service people) and to only give out
One-Time Use codes.
User Information
The installer should advise the user and note in the User’s Manual:
l
Service organization name and telephone number
l
The programmed exit and entry time
l
Instructions to test system weekly
l
Note that the installer code cannot arm or disarm the system
- 269 -