Section 4: System operation
l
Alarm tone
l
Zone Name -Voice Annunciation (HS2LCDWFVPROx keypads only)
The above door chime sounds are programmable in section [861]-[876], subsections [101]-[228].
[*][5] Program access codes
Use this section to perform the following functions:
l
press [1] to program user codes 0002-1000, and master code 0001
l
press [2] to enroll a proximity tag
l
press [3] to add a custom label for each user
l
press [4] to assign users to partitions
l
press [5] to program user attributes
Assign access codes
In order to access alarm system functionality, users must be added to the system. This involves creating a unique access
code and assigning attributes to each user. Access codes are programmed via the [*][5] menu.
Access code types
The alarm system provides the following access code types:
Code
Add User
Delete User
Arm
Disarm
[*][5]
[*][6] [*][8]
Installer
No
No
No
No
No
No
Yes +
Master
All*
All
Yes
Yes
Yes
Yes
No
Maintenance
No
No
Yes
Yes
No
No
No
User
No
No
Yes
Yes
No
No**
No
Supervisor
All but Master
All but Master
Yes
Yes
Yes
Yes
No
Duress
No
No
Yes
Yes
No
No
No
One-time use
No
No
Yes
1/day
No
No
No
+ If section [020] option 7 is on, a user must enter [*][6][Master Code][05] to give the installer permission to access pro-
gramming.
* Can only change master code if section [015] option 6 is off.
** Yes if [023] option 8 is on.
The Installer and Master codes are system codes. They can be changed but not deleted. The other codes are user-defined
and can be added or deleted as necessary. By default, access codes have the same partition and attribute programming as
the code used to program them.
Access codes are either 4, 6 or 8 digits in length, depending on the setting of programming section [041]. Duplicate codes
are not valid.
Note:
EN50131-1 compliant systems using more than 100 access codes shall set the access code to 8 digits (section [041],
option 02).
Installer Code
This code provides access to Installer Programming [*][8]. The installer code is only used to gain access to configure the sys-
tem though [*][8] Installer Programming and does not have access to any other function. This code can be programed by the
installer in section [006][001]. The default is 5555 (4-digit), 555555 (6-digit) or 55555555 (8-digit).
EN
Note:
For EN50131-1 approved installations the installer code cannot change the master code or any other level 3 codes.
Attempting to access the master code from the installers code generates an error tone from the system.
Master Code - Access Code [0001]
By default the master code can access all partitions and can perform any keypad function. This code can be used to program
all access codes, including the supervisor and duress codes.
If section [015] option 6 is on, the master code can only be changed by the installer via Installer Programming.
The default is 1234 (4-digit), 123456 (6-digit) or 12345678 (8-digit).
- 64 -