Section 4: System operation
Section 4: System operation
4.1 Arming and disarming
The following table describes the various arming and disarming methods available.
Table 4-1 Arming/disarming methods
Method
Description
Away Arm
for 2 s [Access Code*]
Stay Arm
for 2 s [Access Code*]
Night Arm
when armed in stay mode [*][1] + [Access Code*]
Disarm
[Access Code]
No-Entry Arming
[*][9] + [Access Code]
Quick Arm/Quick Exit
[*][0] Note: this feature shall not be used in EN50131 certified systems.
* - requiring an access code can be programmed in Section [015]
For detailed arming/disarming instructions, see the PowerSeries Pro User Manual.
4.2 Partition vs. global keypad
Keypads can be configured to control an individual partition or all partitions (see "Keypad partition setup " on page 48).
Single partition operation
Single partition keypads provide access to alarm functionality for an assigned partition.
Single partition keypads behave as follows:
l
Display the armed state of the partition
l
Display open zones, if the zone belongs to the partition the keypad is assigned to
l
Display bypassed zones and allow zone bypassing or creating bypass groups of zones assigned to the keypad par-
tition
l
Display system troubles (system low battery, system component faults/tampers)
l
Display alarms in memory that occurred on the partition
l
Allow the door chime to be enabled/disabled
l
Activate system test (sounds bells/PGMs assigned to the partition)
l
Allow label programming (user labels for the partition)
l
Control command outputs (those assigned to the partition, or global outputs such as smoke detector reset)
l
Display temperature (not evaluated by UL)
Global/multiple partition operation
Global keypads display a list of all active partitions or assigned partitions along with their current state. A valid access code
is required to view partition status. The Global status screen displays the following:
1 2 3 4 5 6 7 8
R A !
N X E P -
R = Ready
X = Exit Delay
A = Armed
E = Entry Delay
! = Alarm
P = Pre-Alert
N = Not Ready
- = Partition not enabled
- 52 -