Section 5: Programming
l
SMS Configuration trouble
l
Alt comm. Fault.
OFF – does not activate if a communications trouble condition is present.
16 – Not Networked
ON – activates if any of the following not networked conditions is present:
l
Zone 001 – 248
l
Keypad 01 – 16
l
Siren 01 – 16
l
Repeater 01 – 08
l
User 01 – 1000 (wireless keys) not networked troubles
OFF – does not activate if a not networked trouble condition is present.
156 – Latched System Event
01 – True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
02 – Timed Output / Latched Output
ON: output remains active until the PGM output timer expires.
OFF: output remains active until an access code has been entered.
04 – Fire Alarm
ON: activates with fire alarm, [F] key, fire zones, 2-wire smoke.
OFF: does not activate with fire alarm.
05 – Panic Alarm
ON: activates on panic alarm (audible or silent).
OFF: does not activate on panic alarm.
06 – Burglary Alarm
ON: activates on burglary alarm.
OFF: does not activate on burglary alarm.
07 – Medical Alarm
ON: activates on medical alarm.
OFF: does not activate on medical alarm.
08 – Supervisory
ON: activates on supervisory alarm.
OFF: does not activate on supervisory alarm.
09 – Priority Event
ON: activates on priority alarm.
OFF: does not activate on priority alarm.
10 – Holdup
ON: activates on holdup alarm.
OFF: does not activate on Holdup alarm.
11 – Duress Alarm
ON: activates on duress alarm.
OFF: does not activate on duress alarm.
12 – Emergency Alarm
ON: activates on emergency alarm.
OFF: does not activate on emergency alarm.
13 – Fire Supervisory
ON: activates on fire supervisory alarm.
- 98 -