Section 5: Programming
OFF: does not activate when the system is disarmed with an alarm in memory.
12 – Emergency Alarm
ON: activates with zone emergency alarm.
OFF: does not activate with zone emergency alarm.
13 – Duress Alarm
ON: activates with duress alarm.
OFF: does not activate with duress alarm.
14 – Hold Up verified
ON: activates when a verified holdup event is detected.
OFF: does not activate when a verified holdup event is detected.
155 – System Trouble
01 – True Output/Inverted
ON: deactivated during normal operation, activated when triggered.
OFF: activated during normal operation, deactivated when triggered.
02 – Timed Output / Latched Output
ON: output remains active until the PGM output timer expires.
OFF: output remains active until an access code has been entered.
04 – Service Required
ON: activates on service required trouble condition.
OFF: does not activate on service required trouble condition.
05 – Loss of Clock
ON: activates on loss of clock trouble condition.
OFF: does not activate on loss of clock trouble condition.
06 – DC Trouble
ON: activates if a panel low or no battery trouble is detected, or if an HSM2204/2300 1-4 low or no battery trouble is
detected.
OFF: does not activate on DC Trouble condition.
07 – Bus Voltage
ON: activates when a system module has measured a low Aux voltage.
OFF: does not activate for a module low voltage trouble.
08 – AC Trouble
ON: activates when any system device detects an AC Failure condition.
OFF: does not activate for AC Failure conditions.
09 – Device Fault
ON: activates if one of the following device fault conditions is present:
l
zone 001 – 248 fault
l
keypad 01 – 16 fault
l
siren 01 – 16 fault
l
repeater 01 – 08 fault
l
fire trouble
l
CO trouble
l
gas trouble
l
heat trouble
l
freeze trouble
l
probe disconnected trouble
l
self test trouble
OFF: does not activate if a device fault condition is present.
10 – Device Low Battery
ON: activates if any of the following device low battery conditions is present: