5-6
SPECIAL INSTRUCTIONS FOR ELECTRONIC SUBSYSTEMS
D
AILY
Base - 02/2012
Printed 603.95.241
Bodybuilder connectors
Table 5.2 - Basic functions of 20 pin connector
Pin
Description
Signal
Remarks
1
Engine start-up
Input
max 20 mA
When positive signal is supplied, the starter
motor is powered and starts the vehicle engine.
Operation takes place only when the key is
turned in the barrel. When starting the vehicle,
NO SAFETY CHECKS OF ANY TYPE ARE
CARRIED OUT e.g. gear engaged etc.
For both normal vehicles and for Start & Stop
vehicles
+12 V = engine start-up
Open circuit - no action
2
Engine shut-down
Input
max 10 mA
When a positive signals is supplied, the vehicle
engine is shut down
+12 V = engine shut-down
Open circuit = no action
3
Service braking
Output
max 500 mA
(interface with uncoupling
diode)
When the brake pedal is pressed, a positive signal
is generated.
+12 V = service brake active
Open circuit = service brake inactive
4
Vehicle stationary
Output
max 500 mA
When the vehicle is stationary, a ground is obtained
Earth = vehicle parked
Open circuit = vehicle in motion
5
Parking brake
Output
max 500 mA
(interface with uncoupling
diode)
When the handbrake is operated, an earth signal
is generated.
Earth = brake engaged
Open circuit = brake released
6
Battery positive
Output
max 20 A
Positive protected by a fuse present on the Body
Computer - F34
7
Exterior light activation
Output
max 500 mA
When the sidelights are on, a positive signal is
obtained
+12 V = lights on
Open circuit = lights off
8
Alternator operation
Output
max 500 mA
(interface with uncoupling
diode)
When the vehicle alternator is cranked, a positive
signal is obtained
+12 V = Battery charging
Open circuit = battery not charging
9
Clutch engagement
Output
max 500 mA
(interface with uncoupling
diode)
When the clutch pedal is pressed, the circuit is
open.
+12 V = clutch engaged
Open circuit = clutch released
10
Reverse engagement
Output
max 500 mA
(interface with uncoupling
diode)
When reverse is engaged, a positive signal is
obtained
+12 V = reverse engaged
Open circuit = reverse engaged
Summary of Contents for DAILY M.Y. 2012
Page 1: ...DAILY M Y 2012 BODYBUILDERS INSTRUCTIONS L I G H T R A N G E ISSUE 2012 ...
Page 4: ...Base 02 2012 Printed 603 95 241 Update data ...
Page 8: ...Index of section Base 02 2012 Printed 603 95 241 ...
Page 10: ...1 2 GENERAL SPECIFICATIONS DAILY Base 02 2012 Printed 603 95 241 Index ...
Page 26: ...1 18 GENERAL SPECIFICATIONS DAILY Base 02 2012 Printed 603 95 241 Convention ...
Page 30: ...2 4 CHASSIS MODIFICATIONS DAILY Base 02 2012 Printed 603 95 241 Index ...
Page 98: ...2 72 CHASSIS MODIFICATIONS DAILY Base 02 2012 Printed 603 95 241 Chocks ...
Page 140: ...4 2 POWER TAKE OFFS DAILY Base 02 2012 Printed 603 95 241 Index ...
Page 214: ...A 2 APPENDIX A DAILY PASSENGER TRANSPORT DAILY Base 02 2012 Printed 603 95 241 Index ...