CHASSIS MODIFICATIONS
2-23
D
AILY
Printed 603.95.241
Base — 02/2012
Change of the rear overhang
The solution foreseen for elongations greater than 350 mm is shown in Figure 2.10.
Figure 2.8
Figure 2.9
Figure 2.10
102427
If the amount of the elongation is considerable, it is necessary to assess on a case by case basis if a supplementary cross member
is needed in order to ensure suitable torsional rigidity for the chassis. A supplementary cross member, with the standard
characteristics, must be inserted when the distance between the two cross members is greater than 1200 mm.