The DPV1 command channel
DPV1 command 31dec (1Fhex):
one-time execution of the "Extended safety monitor protocol" in the "Safety at Work" monitor
11-30
1st to 6th colour output circuit 1/2:
3
2
1
0
Description
0 0 0 0
green,
continuous
0 0 0 1
green,
flashing
0 0 1 0
yellow,
continuous
0 0 1 1
yellow,
flashing
0 1 0 0
red,
continuous
0 1 0 1
red,
flashing
0 1 1 0
grey,
off
Example ("Safety at work" monitor has not switched):
Word no.
Value [hex]
Description
1 076F
07 = reflected user ID 7
6F = command status is "ready" (no fault)
2
001F
1F = reflected command number 31
3 001E
00 = reflected sub command 0
1E = AS-i slave address 30
4
0000
green: contacts of the output circuits closed
5
0000
both output circuits green
6…17
xxxx
not relevant because 5th word = 0000
18
0100
field number = 1
Example ("Safety at work" monitor has switched):
Word no.
Value [hex]
Description
1 076F
07 = reflected user ID 7
6F = command status is "ready" (no fault)
2
001F
1F = reflected command number 31
3 001E
00 = reflected sub command 0
1E = AS-i slave address 30
4 0211
0xxx = output circuit 2 green
x2xx = output circuit 1 red
xx11 = protective operation, output circuit 1 off (in both data calls)
5 0003
result of 4th word = OSSD2 green; OSSD1 not green
03
hex
= provides 3 modules which are not green
6 0421
module
33
dec
(21
hex
) red, continuous (04)
7 0422
module
34
dec
(22
hex
) red, continuous (04)
8 0423
module
35
dec
(23
hex
) red, continuous (04)
9…11 xxxx
not relevant because low byte of 5th word = 03
→
3 modules relevant
12…17 xxxx
not relevant, because high byte of 5th word = 00: green
→
no module relevant
18
0100
field number = 1
Summary of Contents for Ecomat 300 AC1355
Page 8: ...8 15 Terms abbreviations 15 1 16 Index 16 1 ...
Page 12: ...On this manual Overview where is what 1 4 ...
Page 14: ...Safety instructions Functions and features 2 2 ...
Page 16: ...System requirements Required accessories 3 2 ...
Page 18: ...Getting started Set up Profibus DPV1 4 2 ...
Page 24: ...Menu Main menu Fieldbus Setup 6 4 ...
Page 52: ...Set up Finish set up 7 28 ...
Page 238: ...Technical data Profibus DP interface 13 2 ...
Page 246: ...Terms abbreviations 15 6 ...