The DPV1 command channel
Syntax
11-2
In the DPV1 address space a command channel with a length of 19 words is defined for each AS-i
master. A DPV1 master operates as host system.
DPV1 addresses
Start
End
dec
hex
dec
Contents
Access
r = read
w = write
Size [Words]
4794
12BA
4812
master 1 command channel request
r / w
19
4813
12CD
4831
master 1 command channel response
r
19
8890
22BA
8908
master 2 command channel request
r / w
19
8909
22CD
8927
master 2 command channel response
r
19
The commands are always triggered by the DPV1 master by means of a corresponding entry in its
output data area. The controllere responds then in the input data area of the host system.
11.2 Syntax
Request of DPV1 master
Bit
Word
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
1
user ID
command request
2
reserved for string transfers
command number
3...18
command data
19
0
NOTE
If a command is to be executed, the value 65
hex
must be entered in the command request. Changing
the command number does not start the execution. If a command is to be executed several times, the
user ID must be changed accordingly, e.g. by counting up. Before starting a command it should be
verified in the command status whether the previous command has been completed.
Response from controllere (DPV1 slave)
Bit
Word
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
1
reflected user ID
command status
2
reserved for string transfers
reflected command number
3...18
command data
19
0
Summary of Contents for Ecomat 300 AC1355
Page 8: ...8 15 Terms abbreviations 15 1 16 Index 16 1 ...
Page 12: ...On this manual Overview where is what 1 4 ...
Page 14: ...Safety instructions Functions and features 2 2 ...
Page 16: ...System requirements Required accessories 3 2 ...
Page 18: ...Getting started Set up Profibus DPV1 4 2 ...
Page 24: ...Menu Main menu Fieldbus Setup 6 4 ...
Page 52: ...Set up Finish set up 7 28 ...
Page 238: ...Technical data Profibus DP interface 13 2 ...
Page 246: ...Terms abbreviations 15 6 ...