4. Operation
44 TSα Series User Manual
③ Outside Waiting
OutWait : Outside Waiting
When many other auxiliary products are attached on the top of the mold, robot might not able
to wait on the top of the mold until the mold is completely open. Robot has function to wait
outside of IMM, and robot will move to IMM after mold is completely open. ( This is for
minimizing crash with Robot EOAT and Attachments of Mold (Like Hose, Cylinder, Core etc ).
Need to set waiting position outside of the range of Descent ( Down ) Area. Default setting is
“
NoUse
”
.
Display
Description
Motion
NoUse
(=Default)
Robot wait on the top of the mold
until mold is completely open.
Use
Robot wait outside of mold until mold
is open.
Waiting Position
ArmSet
M&S
Method
Vacuum
OutWait
NoUse ◀
Motion
LType