4. Operation
TSα Series User Manual 39
4.1.2 Counter
(1) Description
Counter can be viewed and changed using handy controller.
Counter Mode displays Total Production Quantity , Detection Failure Quantity, Multi Point
Release.
NO
Display
Description
C0
TotQty
Total Operation ( Production ) Quantity y : Robot Operation Cycle after
Reset
C1
DetFai
Detection Failure Quantity
C2
MulRel
Current Multi Release(Off) number and Total Multi Release(Off) number
(2) Button Function
NO
Button
Description
1
Pressing arrow key scroll the > key through the list.
2
Press Clear key will Reset the item on > key. Press more than 2
seconds..
3
Press Stop button to change Manual mode..
4
Press Auto button to back to Auto Mode
>C0
TotQty
10000
C1
DetFai
3
C2 MulRel 2/4
Counter
30
0