8. Error
112 TSα Series User Manual
6.2.4 Sol
valve
NO
Display
Cause
Recovery Method
160 VacuumFail
A.
Vacuum Failure
B.
Check Vacuum Pad
C.
Leaking at Stem and
Fitting
D.
Adjust Vacuum
sensitivity
1.
Open Safety Door and Fix
Problem in Manual Mode
2.
Replace Pad.
3.
Tight Stem and Fitting Screw
161 ChuckFail
1.
Chuck Motion Failure
2.
Chuck Sensor Touch
Failure
3.
Bad Sensor
1.
Open Safety Door and Fix
Problem in Manual Mode
2.
Adjust location of Sensor
3.
Replace Sensor
162 MArmGripFail
1.
Gripper Motion Failure
2.
Wrong Sensor Location
3.
Bad Sensor
1.
Open Safety Door and Fix
Problem in Manual Mode.
2.
Adjust location of Sensor
3.
Replace Sensor
163 SArmGripFail
4.
Gripper Motion Failure
5.
Wrong Sensor Location
6.
Bad Sensor
4.
Open Safety Door and Fix
Problem in Manual Mode.
5.
Adjust location of Sensor
6.
Replace Sensor
6.2.5 Machine
Abnormality
NO
Display
Cause
Recovery Method
176 SCInitiError
1.
Noise
2.
Program Failure
Reboot
Contact Factory
178 OriginFail
( Touch Plate : Origin
Sensor Touch Plate )
1.
Touch Plate Setting
2.
Touch Plate Sensor Bad
3.
Servo Motor Pulley
loosened
4.
Bad Belt
1.
Reset Touch Plate
2.
Change Touch Plate Sensor
3.
Tighten motor Pully
4.
Belt change
179 DownProhibit
Sub Arm Release position
should be within the Descent
ok position
Sub Arm Off position need to
be set after pass the down
prohibit sensor.
Summary of Contents for TS-200DI
Page 2: ......
Page 14: ...xii...
Page 15: ...xiii...
Page 19: ......
Page 20: ......
Page 21: ...1 Introduction...
Page 22: ......
Page 28: ......
Page 29: ...2 Before Operation...
Page 30: ......
Page 41: ...3 START UP STOP...
Page 42: ......
Page 47: ...4 OPERATION...
Page 48: ......
Page 114: ......
Page 115: ...5 Follow Up...
Page 116: ......
Page 126: ......
Page 127: ...6 Error...
Page 128: ......
Page 134: ......
Page 135: ...Appendix...
Page 136: ......
Page 143: ......