NOTE
All the steps must be performed on both the MEP and RMEP unless otherwise specified.
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
mpls-tp meg
meg-name
The maintenance entity group (MEG) view is displayed.
Step 3
Select one of the following sub-procedures as needed.
l
Configure single-ended frame LM.
1.
Run the
lost-measure single-ended receive enable
command to enable the RMEP to
receive LMMs from the MEP.
2.
Run any of the following commands:
–
Run the
loss-measure single-ended
[
interval
interval-value
|
count
count-value
|
exp
exp-value
]
*
command to enable single-ended on-demand frame LM on the
MEP.
–
Run the
lost-measure single-ended proactive
[
interval
interval-value
|
exp
exp-
value
]
*
command to enable single-ended proactive frame LM on the MEP.
3.
(Optional) Run the
lost-measure single-ended loss-ratio
{
threshold1
threshold1-
value
|
sd1-continuous-period
period-length
|
sd1-period
period-value
sd1-count
sd1-
count-value
|
threshold2
threshold2-value
|
sd2-continuous-period
period-length
|
sd2-period
period-value
sd2-count
sd2-count-value
}
*
command to set an alarm
threshold for single-ended frame LM. When the number of dropped frames reaches or
exceeds the alarm threshold, an alarm is generated and an automatic protection
switching (APS) switchover is triggered.
4.
(Optional) Run the
lost-measure single-ended loss-ratio revertive-period
revertive-
period-value
command to set a threshold for an APS switchback. When the number of
times that the number of dropped frames falls below a specified alarm threshold reaches
or exceeds the configured threshold, an APS switchback is triggered.
l
Configure dual-ended frame LM.
1.
(Optional) Run the
cc interval
interval-value
command to configure the interval
between CCM transmissions.
Typical CCM transmission intervals and their application scenarios are as follows:
–
3.3 ms: 300 frames are sent per second. This interval is recommended in protection
switching.
–
100 ms: 10 frames are sent per second. This interval is recommended in performance
monitoring.
–
1000 ms: One frame is sent per second. This interval is recommended in fault
management.
2.
(Optional) Run the
cc exp
exp-value
command to configure the priority of CCMs.
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
9 MPLS-TP OAM Configuration