![Huawei Quidway NetEngine40E Configuration Manual - Reliability Download Page 1032](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_1694531032.webp)
1.
Run:
system-view
The system view is displayed.
2.
Run:
interface
interface-type interface-number
The attachment circuit (AC) interface view is displayed.
3.
Run:
mpls l2vpn pw bit-error-detection
Bit-error-triggered protection switching is enabled on the end PE.
l
Enable bit-error-triggered protection switching for an MS-PW.
1.
Configure each end PE.
a.
Run:
system-view
The system view is displayed.
b.
Run:
interface
interface-type interface-number
The AC interface view is displayed.
c.
Run:
mpls l2vpn pw bit-error-detection
Bit-error-triggered protection switching is enabled on the end PE.
2.
Configure each SPE.
a.
Run:
system-view
The system view is displayed.
b.
Run:
mpls switch-l2vc
ip-address
vc-id
between
ip-address
vc-id
encapsulation
encapsulation-type
bit-error-detection
Bit-error-triggered protection switching is enabled on the SPE.
----End
Checking the Configurations
After configuring bit-error-triggered switching for PW redundancy, run the following commands
to check the configurations:
l
Run the
display bfd bit-error-detection session
all
command. The command output
shows information about all bit error detection sessions.
<HUAWEI>
display bfd bit-error-detection session all
------------------------------------------------------------------------------
--
BFD Bit Error Information:
------------------------------------------------------------------------------
--
Session MIndex : 256
Session Type : PE
FSM Board Id : 1
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
10 Bit-Error-Triggered Protection Switching Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1015