ip 10.102.1.254 auto
[NPE1-bfd-session-link3]
commit
[NPE1-bfd-session-link3]
quit
[NPE1]
bfd link4 bind peer-ip 10.103.1.1 interface gigabitethernet1/0/1.103 source-
ip 10.103.1.254 auto
[NPE1-bfd-session-link4]
commit
[NPE1-bfd-session-link4]
quit
# Configure NPE2.
[NPE2]
bfd
[NPE2-bfd]
quit
[NPE2]
bfd peer1 bind peer-ip 10.1.1.254 interface gigabitethernet1/0/1.1 source-ip
10.1.1.253 auto
[NPE2-bfd-session-peer1]
commit
[NPE2-bfd-session-peer1]
quit
[NPE2]
bfd link1 bind peer-ip 10.100.1.1 interface gigabitethernet1/0/1.100 source-
ip 10.100.1.253 auto
[NPE2-bfd-session-link1]
commit
[NPE2-bfd-session-link1]
quit
[NPE2]
bfd link2 bind peer-ip 10.101.1.1 interface gigabitethernet1/0/1.101 source-
ip 10.101.1.253 auto
[NPE2-bfd-session-link2]
commit
[NPE2-bfd-session-link2]
quit
[NPE2]
bfd link3 bind peer-ip 10.102.1.1 interface gigabitethernet1/0/1.102 source-
ip 10.102.1.253 auto
[NPE2-bfd-session-link3]
commit
[NPE2-bfd-session-link3]
quit
[NPE2]
bfd link4 bind peer-ip 10.103.1.1 interface gigabitethernet1/0/1.103 source-
ip 10.103.1.253 auto
[NPE2-bfd-session-link4]
commit
[NPE2-bfd-session-link4]
quit
# After completing the preceding configurations and BFD configurations on each CE, run the
display bfd configuration all
command on an NPE. The command output shows that the value
of the
Commit
field is
True
.
In the following example, the display on NPE1 is used.
[NPE1]
display bfd configuration all
--------------------------------------------------------------------------------
CFG Name CFG Type LocalDiscr MIndex SessNum Commit AdminDown
--------------------------------------------------------------------------------
peer1 S_AUTO_IF 8192 256 1
True
False
link1 S_AUTO_IF 8193 257 1
True
False
link2 S_AUTO_IF 8194 258 1
True
False
link3 S_AUTO_IF 8195 259 1
True
False
link4 S_AUTO_IF 8196 260 1
True
False
--------------------------------------------------------------------------------
Total Commit/Uncommit CFG Number : 5/0
Run the
display bfd session all
command on an NPE to view the BFD session status. The
command output shows that the value of the
State
field is
Up
.
In the following example, the display on NPE1 is used.
[NPE1]
display bfd session all
--------------------------------------------------------------------------------
Local Remote PeerIpAddr State Type InterfaceName
--------------------------------------------------------------------------------
8192 8192 10.1.1.253
Up
S_AUTO_IF GigabitEthernet1/0/1.1
8193 8192 10.100.1.1
Up
S_AUTO_IF GigabitEthernet1/0/1.100
8194 8193 10.101.1.1
Up
S_AUTO_IF GigabitEthernet1/0/1.101
8195 8194 10.102.1.1
Up
S_AUTO_IF GigabitEthernet1/0/1.102
8196 8195 10.103.1.1
Up
S_AUTO_IF GigabitEthernet1/0/1.103