Run the
display y1731 statistic-type
command to view statistics about dual-ended frame loss.
<HUAWEI>
display y1731 statistic-type dual-loss md md1 ma ma1
Latest dual-ended loss statistics:
--------------------------------------------------------------------------------
Index Local-loss Local-loss ratio Remote-loss Remote-loss ratio
--------------------------------------------------------------------------------
1 0 0.0000% 0 0.0000%
2 0 0.0000% 0 0.0000%
3 5 50.0000% 10 50.0000%
4 0 0.0000% 0 0.0000%
5 5 50.0000% 10 50.0000%
6 10 50.0000% 5 50.0000%
7 5 50.0000% 10 50.0000%
8 10 50.0000% 5 50.0000%
9 10 50.0000% 5 50.0000%
10 5 50.0000% 10 50.0000%
11 5 50.0000% 10 50.0000%
12 10 50.0000% 5 50.0000%
13 5 50.0000% 10 50.0000%
14 10 50.0000% 5 50.0000%
15 5 50.0000% 10 50.0000%
16 10 50.0000% 5 50.0000%
--------------------------------------------------------------------------------
Average Local-loss : 5 Average Local-loss Ratio : 40.6250%
Maximum Local-loss : 10 Maximum Local-loss Ratio : 50.0000%
Minimum Local-loss : 0 Minimum Local-loss Ratio : 0.0000%
Average Remote-loss : 6 Average Remote-loss Ratio : 40.6250%
Maximum Remote-loss : 10 Maximum Remote-loss Ratio : 50.0000%
Minimum Remote-loss : 0 Minimum Remote-loss Ratio : 0.0000%
Configuring One-way Frame Delay Measurement in VPLS Networking
In VPLS networking, the clock frequency between the two ends are synchronized and CFM is
enabled to monitor link connectivity. if the unidirectional delay measurement needs to be
performed for a link, one-way frame delay measurement can be configured to monitor the quality
of the link.
Context
NOTE
Before configuring a unidirectional delay, synchronize the clock frequency between the two ends. For
details about frequency synchronization configuration, see the chapter "1588v2 Configuration" in
Configuration Guide-System Management
.
One-way frame delay measurement in VPLS networking can be either on-demand or proactive.
On-demand one-way frame delay measurement is manually initiated for diagnosis of frame
transmission delays in a limited time. It can be singular or periodic measurement. Proactive one-
way frame delay measurement is carried out continuously to permit proactive reporting of frame
transmission delays or performance results.
l
To implement singular or periodic one-way frame delay measurement for a PW, configure
on-demand one-way frame delay measurement in VLL networking.
l
To implement continual one-way frame delay measurement for a PW, configure proactive
one-way frame delay measurement in VLL networking.
Procedure
l
Configure on-demand one-way frame delay measurement for a PW.
1.
Perform the following steps on the devices at both ends of a PW where one-way frame
delay measurement will be implemented: