![Huawei Quidway NetEngine40E Configuration Manual - Reliability Download Page 78](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_169453078.webp)
Unidirection, 1+1 mode, No Revert mode
No Request on Both Working and Protection Side
------------------------------------------------------------------------
Group Work-Channel Protect-Channel Wtr W-State P-State Switch-Cmd Switch-Result
------------------------------------------------------------------------
1 Cpos 3/0/1 Cpos 3/0/2 NA sf ok NA
switch
------------------------------------------------------------------------
total entry: 1
<PE2>
display cpos-trunk 1
Interface Cpos-Trunk1's state information is:,
Operate status: up Number Of Up Port In Trunk: 2
--------------------------------------------------------------------------------
PortName Status Active Status
Cpos3/0/1
Down
Inactive
Cpos3/0/2 Up
Active
Run the
display mpls l2vc
command on PEs. You can view that the status of the PW is Up and
has not been influenced by the fault of CPOS 3/0/1.
Use the display on PE1 as an example:
<PE1>
display mpls l2vc interface serial2/0/1:0
*client interface : Serial2/0/1:0 is up
session state : up
AC state : up
VC state : up
VC ID : 100
VC type : CESoPSN basic mode
destination : 192.3.3.3
local group ID : 0
remote group ID : 0
local VC label : 146432
remote VC label : 145287
TDM encapsulation number : 40
jitter-buffer : 20
idle-code : FF
rtp-header : disable
local AC OAM State : up
local PSN State : up
local forwarding state : forwarding
local status code : 0x0
remote AC OAM state : up
remote PSN state : up
remote forwarding state: forwarding
remote statuscode : 0x0
BFD for PW : unavailable
manual fault : not set
active state : active
forwarding entry : not exist
link state : up
local VC MTU : 1500
remote VC MTU : 1500
local VCCV : alert lsp-ping bfd
remote VCCV : none
local control word : disable
remote control word : disable
tunnel policy name : --
traffic behavior name : --
PW template name : --
primary or secondary : primary
VC tunnel/token info : 0 tunnels/tokens
create time : 0 days, 4 hours, 48 minutes, 51 seconds
up time : 0 days, 4 hours, 02 minutes, 39 seconds
last change time : 0 days, 0 hours, 39 minutes, 29 seconds
VC last up time : 2008/12/26 12:02:49
VC total up time : 0 days, 4 hours, 02 minutes, 39 seconds
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
3 APS Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
61