# Configure PE2 as the egress for the static bidirectional co-routed LSP from PE2 to PE1
and as the ingress for the static bidirectional co-routed LSP from PE2 to PE3.
[PE2]
bidirectional static-cr-lsp egress tunnel1/0/0
[PE2-bi-static-ingress-Tunnel1/0/0]
forward in-label 20 lsrid 1.1.1.1 tunnel-
id 100
[PE2-bi-static-ingress-Tunnel1/0/0]
backward nexthop 10.1.2.1 out-label 30
bandwidth ct0 10000
[PE2]
bidirectional static-cr-lsp ingress Tunnel/0/2
[PE2-bi-static-ingress-Tunnel1/0/2]
forward nexthop 10.1.4.2 out-label 60
bandwidth ct0 10000
[PE2-bi-static-ingress-Tunnel1/0/2]
backward in-label 70
[PE2-bi-static-ingress-Tunnel1/0/2]
quit
# Configure PE3 as the egress for the static bidirectional co-routed LSPs from PE1 to PE3
and from PE2 to PE3.
[PE3]
bidirectional static-cr-lsp egress tunnel1/0/1
[PE3-bi-static-ingress-Tunnel1/0/1]
forward in-label 40 lsrid 1.1.1.1 tunnel-
id 200
[PE3-bi-static-ingress-Tunnel1/0/1]
backward nexthop 10.1.3.1 out-label 50
bandwidth ct0 10000
[PE3-bi-static-ingress-Tunnel1/0/1]
quit
[PE3]
bidirectional static-cr-lsp egress tunnel1/0/2
[PE3-bi-static-ingress-Tunnel1/0/2]
forward in-label 60 lsrid 2.2.2.2 tunnel-
id 300
[PE3-bi-static-ingress-Tunnel1/0/2]
backward nexthop 10.1.4.1 out-label 70
bandwidth ct0 10000
[PE3-bi-static-ingress-Tunnel1/0/2]
quit
4.
Bind tunnel interfaces on PE2 and PE3 to a static bidirectional co-routed LSP.
# Configure PE2.
[PE2]
interface tunnel1/0/0
[PE2-Tunnel1/0/0]
mpls te passive-tunnel
[PE2-Tunnel1/0/0]
mpls te binding bidirectional static-cr-lsp egress
tunnel1/0/0
[PE2-Tunnel1/0/0]
mpls te commit
[PE2-Tunnel1/0/0]
quit
# Configure PE3.
[PE3]
interface tunnel1/0/1
[PE3-Tunnel1/0/1]
mpls te passive-tunnel
[PE3-Tunnel1/0/1]
mpls te binding bidirectional static-cr-lsp egress
tunnel1/0/1
[PE3-Tunnel1/0/1]
mpls te commit
[PE3-Tunnel1/0/1]
quit
[PE3]
interface tunnel1/0/2
[PE3-Tunnel1/0/2]
mpls te passive-tunnel
[PE3-Tunnel1/0/2]
mpls te binding bidirectional static-cr-lsp egress
tunnel1/0/2
[PE3-Tunnel1/0/2]
mpls te commit
[PE3-Tunnel1/0/2]
quit
Run the
display mpls te bidirectional static-cr-lsp
command on PE1, PE2, and PE3, and
you can view information about the static bidirectional LSPs.
# Check the configuration on PE1.
[PE1]
display mpls te bidirectional static-cr-lsp
TOTAL : 2 STATIC CRLSP(S)
UP : 2 STATIC CRLSP(S)
DOWN : 0 STATIC CRLSP(S)
Name FEC I/O Label I/O If
Status