![Huawei Quidway NetEngine40E Configuration Manual - Reliability Download Page 824](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_169453824.webp)
Single-ended frame loss measurement is implemented for the link between the local
MEP and a remote MPE identified by an ID or a MAC address.
–
If the local MEP has not learned the MAC address of the remote MEP, the MAC
address of the remote MEP must be specified to implement single-ended frame
loss measurement.
–
If the local MEP has learned the MAC address of the remote MEP, the ID of the
remote MEP can be used to implement single-ended frame loss measurement.
l
Configure proactive single-ended frame loss measurement.
1.
Perform the following steps on the devices at both ends of a link where proactive
single-ended frame loss measurement will be implemented:
a.
Run:
system-view
The system view is displayed.
b.
(Optional) Run:
y1731 record-mode detailed
The detailed mode for recording Y.1731 proactive statistics is enabled.
c.
(Optional) Run:
y1731 pm-mode enable
Performance management (PM) to manage Y.1731 proactive performance
statistics is enabled. PM saves the statistics to generated statistics files and then
sends the files to the NMS.
By default, PM is disabled from managing Y.1731 proactive performance
statistics.
d.
(Optional) Run:
y1731 record-upload
A device is enabled to send Y.1731 proactive performance statistics files to a
server.
The
y1731 pm-mode enable
and
y1731 record-upload
commands are mutually
exclusive.
e.
Run:
cfm md
md-name
The MD view is displayed.
f.
Run:
ma
ma-name
The MA view is displayed.
g.
Run:
mapvlanvlan-id
The MA is bound to a VLAN.
h.
Run:
mep mep-id
The MEP is configured.
i.
Run:
remote-mep mep-id
mep-id
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
807