Associating Ethernet OAM with Ethernet OAM
You can configure the fault notification mode as required.
Context
Perform the following steps on the CEs:
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
oam-mgr
The OAM management view is displayed.
Step 3
Run the following command as required.
l
Run:
oam-bind cfm md
md-name
ma
ma-name
efm
interface
interface-type
interface-number
The bidirectional transmission of fault messages between EFM OAM and Ethernet CFM is
configured.
l
Run:
oam-bind ingress efm interface
interface-type
interface-number
egress
cfm
md
md-
name
ma
ma-name
EFM OAM is configured to send fault messages to Ethernet CFM.
l
Run:
oam-bind ingress cfm md
md-name
ma
ma-name
egress
efm
interface
interface-type
interface-number
Ethernet CFM is configured to send fault messages to EFM OAM.
l
Run:
oam-bind ingress cfm md
md-name1
ma
ma-name1
egress
cfm
md
md-name2
ma
ma-name2
Ethernet CFM at one side is configured to send fault messages to Ethernet CFM at the other
side.
l
Run:
oam-bind cfm md
md-name1
ma
ma-name1
cfm
md
md-name2
ma
ma-name2
The bidirectional transmission of fault messages between Ethernet CFMs at both sides is
configured.
NOTE
After Ethernet OAM is associated with other functional modules, note the following:
l
If EFM OAM is disabled on an interface, the association between EFM OAM and other functional
modules is deleted.
l
If an MA or MD is deleted, the association between Ethernet CFM and other functional modules is
deleted.
----End