![Huawei Quidway NetEngine40E Configuration Manual - Reliability Download Page 1076](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_1694531076.webp)
LSPs) of the bidirectional RSVP-TE tunnel are UPE <-> P1 <-> SPE and UPE <-> P2 <-> SPE,
respectively. In normal circumstances, traffic between the UPE and SPE travels along the
primary CR-LSP UPE <-> P1 <-> SPE. If a bit error event occurs on GE1/0/0 of the UPE, traffic
traveling along the primary CR-LSP is affected. To resolve this problem, configure bit-error-
triggered RSVP-TE tunnel switching to enable the bidirectional RSVP-TE tunnel to switch
traffic to the backup CR-LSP if a bit error event occurs on the primary CR-LSP.
NOTE
The thresholds for bit-error-triggered protection switching and revertive switching can be configured. If
the total bit error rate (BER) of the primary CR-LSP exceeds the threshold for bit-error-triggered protection
switching, the bidirectional RSVP-TE tunnel determines whether to perform a primary/backup CR-LSP
switchover. The bidirectional RSVP-TE tunnel performs a primary/backup CR-LSP switchover if the
backup CR-LSP is in the normalized BER state. If the primary and backup CR-LSPs are both in the
excessive BER state, traffic still travels along the primary CR-LSP. In actual situations, configure the
thresholds for bit-error-triggered protection switching and revertive switching based on the sensitivity of
services to bit errors.
Figure 10-4
Networking diagram for bit-error-triggered RSVP-TE tunnel switching
RSVP-TE Tunnel
UPE
SPE
GE1/0/0
GE1/0/1
GE1/0/0
GE1/0/1
GE1/0/0
P1
P2
NodeB
RNC
BSC
GE1/0/1
GE1/0/0
GE1/0/1
Aggregation
Network
Bit error event
Table 10-3
Interface IP address list
Device
Interface
IP Address
UPE
GE1/0/0
172.1.1.1/24
GE1/0/1
172.1.2.1/24
Loopback0
1.1.1.1/32
P1
GE1/0/0
172.1.1.2/24
GE1/0/1
172.1.3.1/24
Loopback0
2.2.2.2/32
P2
GE1/0/0
172.1.2.2/24
GE1/0/1
172.1.4.1/24
Loopback0
3.3.3.3/32
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
10 Bit-Error-Triggered Protection Switching Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.