![Huawei Quidway NetEngine40E Configuration Manual - Reliability Download Page 748](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_169453748.webp)
NOTE
This task is supported in P2P scenarios.
i.
Run:
remote-mep mep-id
mep-id
The remote MEP ID is configured.
j.
Run:
mep ccm-send enable
The CCM transmission function is enabled.
k.
Run:
remote-mep ccm-receive
[
mep-id
mep-id
]
enable
The CCM reception function is enabled.
2.
On the receiving device on a PW where proactive single-ended frame loss
measurement will be implemented, run:
Table 8-26
Configurations for enabling the receive end to receive LMMs
Usage
Scenario
Step
P2P
scenario
Non-test instance-based statistics
Run the
loss-measure single-ended receive
mep
mep-id
[
8021p
{
8021p-value
} &<1–3> ] command to enable the RMEP to receive
LMMs.
If the
8021p
8021p-value
parameter is specified, the device that is to
receive LMMs computes the frame loss ratio based on the specified
802.1p priority. If this parameter is not specified, the device that is to
receive LMMs computes the frame loss ratio for all packets.
Test instance-based statistics
1. Run the
test-id
test-id
command to configure a test instance.
2. Run the
loss-measure single-ended receive test-id
test-id
command to enable the RMEP to receive LMMs.
P2MP
scenario
1. Run the
test-id
test-id
command to configure a test instance for a
specific RMEP.
2. Run the
loss-measure single-ended receive test-id
test-id
command to enable the RMEP to receive LMMs.
3.
On the transmitting device of a PW where proactive single-ended frame loss
measurement will be implemented, run:
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
731