![Huawei Quidway NetEngine40E Configuration Manual - Reliability Download Page 878](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_169453878.webp)
# Configure PE2.
<HUAWEI>
system-view
[HUAWEI]
sysname PE2
[PE2]
cfm enable
[PE2]
cfm version standard
[PE2]
cfm md md1
[PE2-md-md1]
ma ma1
[PE2-md-md1-ma-ma1]
map mpls l2vc 2 tagged
[PE2-md-md1-ma-ma1]
mep mep-id 2 interface gigabitethernet1/0/1.1 inward
[PE2-md-md1-ma-ma1]
mep ccm-send mep-id 2 enable
[PE2-md-md1-ma-ma1]
remote-mep mep-id 1
[PE2-md-md1-ma-ma1]
remote-mep ccm-receive mep-id 1 enable
3.
Configure the DMM reception function on PE2.
# Configure PE2.
[PE2-md-md1-ma-ma1]
delay-measure two-way receive mep 2
[PE2-md-md1-ma-ma1]
quit
[PE2-md-md1]
quit
4.
Enable on-demand two-way frame delay measurement for the PW on the VLL network.
# Configure PE1.
[PE1-md-md1-ma-ma1]
delay-measure two-way send mep 1 remote-mep 2 interval
1000 count 60
[PE1-md-md1-ma-ma1]
quit
[PE1-md-md1]
quit
5.
Verify the configuration.
Run the
display y1731 statistic-type
command on PE1 to view the statistics about the
delay in bidirectional frame transmission.
<PE1>
display y1731 statistic-type twoway-delay md md1 ma ma1
Latest two-way delay statistics:
------------------------------------------------------------------------------
--
Index Delay(usec) Delay variation(usec)
------------------------------------------------------------------------------
--
1 0 -
2 0 0
3 0 0
4 0 0
5 0 0
6 0 0
7 0 0
8 0 0
9 0 0
10 0 0
------------------------------------------------------------------------------
--
Average delay(usec) : 0 Average delay variation(usec) : 0
Maximum delay(usec) : 0 Maximum delay variation(usec) : 0
Minimum delay(usec) : 0 Minimum delay variation(usec) : 0
Step 2
Configure proactive two-way frame delay measurement for the PW.
NOTE
Proactive two-way frame delay measurement can be configured to continuously monitor the performance
of a PW.
1.
Configure the DMM reception function on PE2.
# Configure PE2.
[PE2-md-md1-ma-ma1]
delay-measure two-way receive mep 2
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
861