![Huawei Quidway NetEngine40E Configuration Manual - Reliability Download Page 1185](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_1694531185.webp)
quit
Exit from the interface view.
5.
Run:
remote-backup-service
service-name
The remote backup service view is displayed.
6.
Run:
web-auth-server source
[
vpn-instance
vpn-instance-name
]
source-ip-
address
The loopback interface's IP address is configured as the BAS-IP address used
independently by the web authentication server.
l
Configure the source IP address of the master and slave devices as the NAS-IP address of
the RADIUS authorization server.
1.
Run:
system-view
The system view is displayed.
2.
Run:
interface
interface-type
interface-number
The interface view is displayed.
3.
Run:
ip address
An IP address is configured for the interface.
4.
Run:
quit
Exit from the interface view.
5.
Run:
remote-backup-service
service-name
The remote backup service view is displayed.
6.
Run:
radius-authorization source
same-as
nas-logic-ip
Or,
radius-authorization source
[
vpn-instance
vpn-instance-name
]
source-ip-
address
The source IP address of the master and slave devices is configured as the NAS-IP
address of the RADIUS authorization server.
NOTE
If a NAS-IP address has been specified in the RADIUS server template, using the
radius-
authorization source
same-as
nas-logic-ip
command is recommended. If a NAS-IP address
is not specified in the RADIUS server template, using the
radius-authorization source
[
vpn-
instance
vpn-instance-name
]
source-ip-address
command is recommended.
----End
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
11 Multi-node Backup Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1168