1.
Configure a VLL connection.
Configure a VLL connection between PE1 and PE2. The configuration details are not
provided here. For details, see the chapter "VLL Configuration" in the
HUAWEI
NetEngine80E/40E Router Configuration Guide - VPN
or configuration files in this
configuration example.
After completing the configuration, run the
display mpls l2vc
command on each PE to
view information about the VC and AC.
<PE1>
display mpls l2vc
total LDP VC : 1 1 up 0 down
*client interface : GigabitEthernet1/0/1.1
Administrator PW : no
session state : up
AC status : up
VC state : up
Label state : 0
Token state : 0
VC ID : 2
VC type : VLAN
destination : 2.2.2.2
local VC label : 1027 remote VC label : 1025
control word : disable
forwarding entry : exist
local group ID : 0
manual fault : not set
active state : active
link state : up
local VC MTU : 1500 remote VC MTU : 1500
tunnel policy name : --
traffic behavior name: --
PW template name : --
primary or secondary : primary
create time : 0 days, 0 hours, 1 minutes, 12 seconds
up time : 0 days, 0 hours, 0 minutes, 42 seconds
last change time : 0 days, 0 hours, 0 minutes, 42 seconds
VC last up time : 2010/10/13 15:02:23
VC total up time : 0 days, 0 hours, 0 minutes, 42 seconds
CKey : 4
NKey : 3
AdminPw interface : --
AdminPw link state : --
2.
Configure basic Ethernet CFM functions and specify the MEP type as inward.
Configure basic Ethernet CFM functions on each PE. Specify the Ethernet CFM protocol
in the version of IEEE Standard 802.1ag-2007. Create an MD named
md1
and an MA
named
ma1
, and bind the MA to the VLL.
# Configure PE1.
<HUAWEI>
system-view
[HUAWEI]
sysname PE1
[PE1]
cfm enable
[PE1]
cfm version standard
[PE1]
cfm md md1
[PE1-md-md1]
ma ma1
[PE1-md-md1-ma-ma1]
map mpls l2vc 2 tagged
[PE1-md-md1-ma-ma1]
mep mep-id 1 interface gigabitethernet1/0/1.1 inward
[PE1-md-md1-ma-ma1]
mep ccm-send mep-id 1 enable
[PE1-md-md1-ma-ma1]
remote-mep mep-id 2
[PE1-md-md1-ma-ma1]
remote-mep ccm-receive mep-id 2 enable
# Configure PE2.
<HUAWEI>
system-view
[HUAWEI]
sysname PE2
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential