The MEP is configured.
f.
Run:
remote-mep mep-id
mep-id
The remote MEP ID is configured.
g.
Run:
mep ccm-send enable
The CCM transmission function is enabled.
h.
Run:
remote-mep ccm-receive
[
mep-id
mep-id
]
enable
The CCM reception function is enabled.
2.
On the receiving device of an AC where single-ended frame loss measurement will
be implemented, run:
Table 8-46
Configurations for enabling the receive end to receive LMMs
Usage
Scenario
Step
P2P
scenario
Non-test instance-based statistics
Run the
loss-measure single-ended receive
mep
mep-id
command
to enable the RMEP to receive LMMs.
Test instance-based statistics
1. Run the
test-id
test-id
command to configure a test instance.
2. Run the
loss-measure single-ended receive test-id
test-id
command to enable the RMEP to receive LMMs.
P2MP
scenario
1. Run the
test-id
test-id
command to configure a test instance for a
specific RMEP.
2. Run the
loss-measure single-ended receive test-id
test-id
command to enable the RMEP to receive LMMs.
3.
On the transmitting device of an AC where single-ended frame loss measurement will
be implemented, run:
Table 8-47
Configurations for enabling a MEP to send LMMs
Usage
Scenario
Step
P2P
scenario
Run the
loss-measure single-ended
send
mep
mep-id
[
mac
mac-
address
|
remote-mep
mep-id
]
interval
interval
count
count-value
command to enable single-ended frame loss measurement on the AC
side.
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
767