Take the display on NPE2 as an example.
[NPE2]
display mpls oam egress all verbose
-------------------------------------------------------------------------
Verbose information about the NO.1 oam at the egress
-------------------------------------------------------------------------
lsp basic information: oam basic information:
----------------------------------- -----------------------------------
Lsp name : -- Oam-Index : 256
Lsp signal status : Up Oam select board : 1
Lsp establish type : Rsvp lsp Enable-state : --
Lsp incoming Label : 3 Auto-protocol : Enable
Lsp ingress lsr-id : 2.2.2.2 Auto-overtime (s) : 300
Lsp tnl-id/lsp-id : 100/1 Ttsi/lsr-id : 2.2.2.2
Lsp Incoming-int : GigabitEthernet2/0/0 Ttsi/tunnel-id : 100
oam detect information: oam backward information:
------------------------------------ ----------------------------------
Type : FFD Tunnel name : Tunnel2/0/0
Frequency : 100 ms Share attribute : Private
Detect-state : Start Lsp signal status : Up
Defect-state :
Non-defect
Bdi-frequency : Detect-freq
Available state : Available
Unavailable time (s): 0
-------------------------------------------------------------------------
Total Oam Num: 1
Total Start Oam Num: 1
Total Defect Oam Num: 0
Total Unavaliable Oam Num: 0
Step 7
Configure EFM OAM on UPEs and NPEs.
# Configure UPE1.
[UPE1]
efm enable
[UPE1]
interface gigabitethernet 1/0/0
[UPE1-GigabitEthernet1/0/0]
efm enable
[UPE1-GigabitEthernet1/0/0]
quit
# Configure NPE1.
[NPE1]
efm enable
[NPE1]
interface gigabitethernet 1/0/0
[NPE1-GigabitEthernet1/0/0]
efm enable
[NPE1-GigabitEthernet1/0/0]
quit
# Configure UPE2.
[UPE2]
efm enable
[UPE2]
interface gigabitethernet 1/0/0
[UPE2-GigabitEthernet1/0/0]
efm enable
[UPE2-GigabitEthernet1/0/0]
quit
# Configure NPE2.
[NPE2]
efm enable
[NPE2]
interface gigabitethernet 1/0/0
[NPE2-GigabitEthernet1/0/0]
efm enable
[NPE2-GigabitEthernet1/0/0]
quit
After the preceding configuration, run the
display efm session
command on UPEs or NPEs.
You can view that the status of EFM OAM on GE 1/0/0 is detect. Take the display on UPE2 as
an example.
[UPE2]
display efm session interface gigabitethernet 1/0/0
Interface EFM State Loopback Timeout
--------------------------------------------------------------------
GigabitEthernet1/0/0
detect
--
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
605