To suppress alarm flapping, you can set the anti-jitter time during alarm generation.
l
VLAN or VLAN chain
All interfaces of the specified VLAN generate MIPs according to the configured MIP
generation rule in the MD.
Pre-configuration Tasks
None.
Data Preparation
To adjust parameters of Ethernet CFM, you need the following data.
No.
Data
1
(Optional) RMEP activation time
2
(Optional) Anti-jitter time during alarm restoration
3
(Optional) Anti-jitter time during alarm generation
(Optional) Configuring the RMEP Activation Time
The RMEP activation time is reserved for you to configure an RMEP. After the configuration
of the RMEP activation time, the local device can receive CCMs after the configured RMEP
activation time expires.
Context
Perform the following steps on each edge device in an MA:
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
cfm md
md-name
The MD view is displayed.
Step 3
Run:
ma
ma-name
The MA view is displayed.
Step 4
Run:
active time
time
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
490