![Huawei Quidway NetEngine40E Configuration Manual - Reliability Download Page 832](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_169453832.webp)
continue the test and send test packets at a lower rate. The bisection method is used to send test
packets at different rates between the upper and lower rate thresholds. The test process repeats
until a maximum bandwidth is found when no packets are dropped in a test. In addition, check
for bit errors on MEP2 that receives test packets.
Figure 8-61
ETH-test function for a VLAN network
VLAN
PE2
CE1
CE2
PE1
MEP1
MEP2
ETH-TEST
Procedure
Step 1
Perform the following steps on PEs:
1.
Run:
system-view
The system view is displayed.
2.
Run:
cfm enable
CFM is enabled globally.
By default, CFM is disabled globally.
3.
Run:
cfm md
md-name
The MD view is displayed.
4.
Run:
ma
ma-name
The MA view is displayed.
5.
Run:
map
vlan
vlan-id
The MA is associated with a VLAN.
6.
Run:
mep mep-id
A MEP is configured.
7.
Run:
eth-test enable
The ETH-test function is enabled.
By default, the ETH-test function is disabled.
8.
Run:
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
815