No.
Data
5
(Optional) ID of an RMEP and MAC address of the interface where the RMEP resides
6
Interval for MEPs sending CCMs in an MA
Configuring Ethernet CFM on PEs on a VPLS
Context
NOTE
l
If 802.1ag MAC trace needs to be implemented to locate the connectivity fault between the PEs, you
cannot specify the outbound interface for sending trace packets.
l
The current MA must be associated with a VSI and the type of the MEP must be inward-facing. After
an MEP is bound to an interface through which a PW passes, the MEP is an outward-facing MEP.
Perform the following steps on the PEs:
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
cfm md
md-name
[
level
level
]
An MD is created and the MD view is displayed.
Step 3
Run:
ma
ma-name
An MA is created and the MA view is displayed.
Step 4
Run:
map
vsi
vsi-name
The MA is associated with a VSI.
Step 5
Configure a MEP based on the interface type.
Table 8-10
MEP configurations on different interfaces
Interface Type
Configuration Note
Common interface
Run the
mep mep-id
mep-id
interface
interface-type interface-
number.subnumber
inward
command to create a MEP.
QinQ termination sub-
interface
Run the
mep mep-id
mep-id
interface
interface-type interface-
number.subnumber
pe-vid
pe-vid
ce-vid
ce-vid
inward
command
to create a MEP.
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration