![Huawei Quidway NetEngine40E Configuration Manual - Reliability Download Page 879](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_169453879.webp)
2.
Enable proactive two-way frame delay measurement.
# Configure PE1.
[PE1-md-md1-ma-ma1]
delay-measure two-way continual send mep 1 remote-mep 2
interval 30000
[PE1-md-md1-ma-ma1]
quit
[PE1-md-md1]
quit
3.
Verify the configuration.
Run the
display y1731 statistic-type
command on PE1 to view the statistics about the
delay in bidirectional frame transmission.
<PE1>
display y1731 statistic-type twoway-delay md md1 ma ma1
Latest two-way delay statistics
------------------------------------------------------------------------------
--
Index Delay(usec) Delay variation(usec)
------------------------------------------------------------------------------
--
1 0 -
2 0 0
3 0 0
------------------------------------------------------------------------------
--
Average delay(usec) : 0 Average delay variation(usec) : 0
Maximum delay(usec) : 0 Maximum delay variation(usec) : 0
Minimum delay(usec) : 0 Minimum delay variation(usec) : 0
----End
Configuration Files
l
Configuration file of CE1
#
sysname CE1
#
vlan batch 2
#
cfm version standard
cfm enable
#
cfm md md1
ma ma2
map vlan 2
mep mep-id 3 interface GigabitEthernet1/0/1 outward
mep ccm-send mep-id 3 enable
remote-mep mep-id 4
remote-mep ccm-receive mep-id 4 enable
#
return
l
Configuration file of PE1
#
sysname PE1
#
cfm version standard
cfm enable
#
mpls lsr-id 1.1.1.1
mpls
#
mpls l2vpn
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
862