Table 8-65
MEP configuration
Operation
Command
Configure
an
interface-
based MEP.
mep mep-id
mep-id
interface
{
interface-type interface-
number
|
interface-type interface-number.subnumber
}
[ {
pe-vid
pe-vid
ce-vid
ce-vid
|
vlan
vlan-id
} ]
Configure a
PW-based
MEP.
mep mep-id
mep-id
peer-ip
peer-ip
[
vc-id
vc-id
] [
mac
mac-address
] {
outward
|
inward
}
f.
Run:
remote-mep mep-id
mep-id
A remote MEP (RMEP) is specified.
g.
Run:
mep ccm-send enable
The MEP is enabled to send continuity check messages (CCMs).
This command can be configured only on an interface-based MEP.
h.
Run:
remote-mep ccm-receive
[
mep-id
mep-id
]
enable
The RMEP is enabled to receive CCMs.
i.
Run:
test-id
test-id-value
mep
mep-id
remote-mep
mep-id
[
description
description
]
A test instance is created.
2.
Perform the following configuration on the RMEP that receives SLM frames on
the PW side:
Run:
loss-measure single-ended-synthetic receive
test-id
test-id
[
time-out
timeout-value
]
The RMEP is enabled to receive SLM frames.
3.
Perform the following configuration on the MEP that sends SLM frames to initiate
on-demand SLM on the PW side:
Run:
loss-measure single-ended-synthetic send
test-id
test-id
interval
interval
[
sending-count
count-value
] [
timeout
timeout
]
The MEP is enabled to send SLM frames.
–
Configure single-ended on-demand SLM on the AC side.
1.
Perform the following steps on the devices at both ends of an AC where single-
ended on-demand SLM will be implemented:
a.
Run:
system-view
The system view is displayed.
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential