![Huawei Quidway NetEngine40E Configuration Manual - Reliability Download Page 743](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_169453743.webp)
Figure 8-48
Networking diagram for priority-based frame loss measurement on a VLL
CE1
PE1
PE2
CE2
User
Network
User
Network
MEP
Y.1731
P
Priority 1
Priority 2
Procedure
l
Configure on-demand single-ended frame loss measurement.
–
Configure on-demand single-ended frame loss measurement for a PW.
1.
Perform the following steps on the PEs at both ends of a PW where single-ended
frame loss measurement will be implemented:
a.
Run:
system-view
The system view is displayed.
b.
Run:
cfm md
md-name
The MD view is displayed.
c.
Run:
ma
ma-name
The MA view is displayed.
d.
Run:
map mpls l2vc
vc-id
{
raw
|
tagged
}
The MA is bound to a specified L2VC.
e.
Run:
mep mep-id
The MEP is configured.
f.
(Optional) Run:
measure-point
mep
mep-id
{
ac
|
pw
}
A measurement point for collecting Y.1731 statistics is configured.
By default, a measurement point for collecting Y.1731 statistics is a PW
interface.
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
726